Direct connection
Connects to PLC, DCS or computer-based alarm systems without extra hardware.
The C12-17 from Badger Meter (GasSens / ATi) is a stand-alone, explosion-proof transmitter that detects combustible gases and hydrocarbon vapours in ambient air and sends a 4-20 mA signal for 0–100% LEL.

The C12-17 detects potentially hazardous concentrations of combustible gases and vapours such as methane, propane, butane, gasoline, toluene and hydrogen in process buildings, analyser enclosures, pump stations and gas compressor stations.
It is a three-wire transmitter supplied as a blind unit or with an integral LCD visible through the window of the explosion-proof housing. Units with display also have a single latching alarm relay that can be reset with a magnetic tool without opening the enclosure.
The catalytic sensor uses an active and a passive element in a Wheatstone bridge. Sensor assemblies are 316 stainless steel with a sinter-bonded flame arrestor; sensor life is typically two years or more.
Connects to PLC, DCS or computer-based alarm systems without extra hardware.
3-digit LCD with latching SPDT relay.
316 stainless steel with flame arrestor.
Reset the alarm without opening the housing.
Item names and order numbers as published by Badger Meter.

NDIR transmitter for methane, hydrocarbons and CO2; ATEX / IECEx, HART or Modbus.

Explosion-proof detector for up to 46 toxic and combustible sensors; loop, HART, relays or Modbus.
Our Biotechnology team in Egypt will help you choose the right configuration, sensors and accessories for your site.
Explore other products available within the same product category and open each page for complete technical details.
Modular sensor transmitters and receivers with display, alarms and optional AutoTest.
60 interchangeable smart sensors, daily AutoTest, heated and remote sensor options, data logger.
Explosion-proof detector for up to 46 toxic and combustible sensors; loop, HART, relays or Modbus.
NDIR transmitter for methane, hydrocarbons and CO2; ATEX / IECEx, HART or Modbus.
Infrared NH3 detector from ppm to explosive levels; no known sensor poisons.
Wet H2S sensor with automatic air purge, 0–2/20/200 ppm, two relays and data logger.
Loop-powered transmitter with 100% RH sensor for Cl2, Br2, ClO2, O3, HCl, HF and H2.
Loop-powered 4-20 mA transmitter for many gases; battery-capable and explosion-proof option.
Intrinsically safe version of the F12 with smart sensors, AutoTest and HART option.
Two H2O2 channels (0–2000 and 0–100 ppm) for sterilisation cycle validation.
Share your requirements — our specialists reply within one working day.
Share your requirements — our team will route your inquiry to the right division and reply within one working day.