Technician operating cleanroom process equipment
After Sales Services & Calibration Center

After-Sales Services & Accredited Calibration

From general calibration conducted in strict alignment with ISO/IEC 17025:2017 to specialized services provided under the trust and authorization of leading global manufacturers, e.g. Merck – Germany.

  • EGACISO/IEC 17025:2017 accredited calibration
  • EndorsedManufacturer-authorized engineers
  • Egypt +6Markets served beyond Egypt
Service Lifecycle

Support across the full equipment lifecycle

Not limited to repair and spare parts replacement: our service center supports customers after equipment delivery, during routine operation, and whenever calibration, maintenance or technical support is required.

  1. Step 01Install
  2. Step 02Commission
  3. Step 03Train
  4. Step 04Maintain
  5. Step 05Repair
  6. Step 06Calibrate
  7. Step 07Qualify
  8. Step 08Validate
Equipment installation and commissioning in a cleanroom
01 – 02

Install & Commission

Installation and commissioning of supplied equipment, according to each manufacturer's requirements.

Engineer training an operator on equipment controls
03

Train

Operator training, user guidance and training coordination.

Technician performing equipment maintenance
04 – 05

Maintain & Repair

Preventive maintenance, maintenance planning, technical troubleshooting and repairs.

Engineer documenting equipment qualification on a tablet
06 – 08

Calibrate, Qualify & Validate

Accredited calibration, plus manufacturer-endorsed calibration and qualification for specialized equipment.

Accredited Calibration Scope

Instruments we calibrate under ISO/IEC 17025:2017

Accredited calibration services for critical measuring instruments, supporting accuracy, compliance, and operational reliability across professional environments.

Pressure gauges on an industrial test line
01Pressure Gauges0 bar to 60 barDKD R 6-1:2014Why it matters

Conducted in full compliance with DKD R 6-1:2014 international guidelines to ensure precise pressure readings across various industrial applications.

Pressure gauges are vital for maintaining safe and efficient operations in industries such as manufacturing, petrochemicals, HVAC, and healthcare. Inaccurate readings can lead to equipment damage, process inefficiencies, or safety hazards.

02Vacuum Gauges-0.9 bar to 0 barDKD R 6-1:2014Why it matters

Performed following DKD R 6-1:2014 standards to guarantee optimal accuracy for vacuum measurement systems.

Accurate vacuum measurements are critical in applications like semiconductor manufacturing, medical equipment testing, and scientific research. Incorrect readings may compromise product quality or lead to equipment malfunction.

03Digital Thermometers+35 °C to +350 °CEURAMET cg-08/Ver 3.1 (02/2020)Why it matters

Aligned with the stringent EURAMET cg-08/Ver 3.1 (02/2020) guidelines to ensure highly accurate temperature readings for both research and industrial environments.

Temperature control is essential in laboratories, food production, medical environments, and manufacturing. Even slight inaccuracies can affect product quality, safety, or research outcomes.

04Non-Automatic Weighing BalancesUp to 220 g · >220 g to 500 g · >500 g to 8 kg · >8 kg to 20 kgOIML R76:2006Why it matters

All balance calibrations are conducted according to the OIML R76:2006 guidelines, ensuring exceptional precision across a wide spectrum of weighing applications, from laboratory scales to heavy-duty industrial platforms.

Accurate weighing is essential in industries such as pharmaceuticals, food production, agriculture, and manufacturing. Miscalibrated balances can result in material loss, financial discrepancies, or compromised product quality.

05Closed Volume at Working Point and Several Locations-20 °C to 0 °C · >0 °C to 200 °C · >200 °C to 350 °CSOP-7.2.1-04 · DKD R 5-7-01:2025Why it matters

Calibration is performed according to SOP-7.2.1-04 and based on DKD R 5-7-01:2025.

Accurate temperature distribution within freezers, refrigerators, incubators, baths, ovens, and autoclaves helps verify that operating conditions remain controlled throughout the working volume.

06Thermo-Hygrometers, Thermo-Hygrographs and Data Loggers20 % to 90 % · 5 °C to 30 °C · >30 °C to 60 °CSOP-7.2.1-05 · ES 1001-01:2023 · DKD R 5-8-10:2019Why it matters

Calibration is performed according to SOP-7.2.1-05 and based on ES 1001- 01:2023 and DKD R 5-8-10:2019.

Reliable temperature and relative humidity readings are important for environmental monitoring, storage conditions, laboratories, and processes where changing ambient conditions can affect results or materials.

07pH Meter4 pH · 7 pH · 10 pHSOP-7.2.1-09 · IEC 60746-1:2003 · IEC 60746-2:2003 · ISO 10523-02:2012Why it matters

Calibration is performed according to SOP-7.2.1-09 and based on IEC 60746-1 :2003, IEC 60746-2 :2003, and ISO 10523 - 02:2012.

Accurate pH measurement supports reliable testing and process monitoring in laboratories, water applications, quality control, and other activities where acidity or alkalinity must be measured correctly.

08Conductivity Meter84 µS/cm · 147 µS/cm · 1413 µS/cm · 12880 µS/cmSOP-7.2.1-10 · ASTM D1125:2023 · IEC 60746-1:2003 · IEC 60746-3:2002Why it matters

Calibration is performed according to SOP-7.2.1-10 and based on ASTM D1125:2023, IEC 60746-1 :2003, and IEC 60746-3 :2002.

Accurate conductivity measurement supports reliable assessment of dissolved ionic content in water and process samples, helping laboratories and operations maintain consistent measurement results.

09Rotational Speed Devices25 to <100 · 100 to <1000 · 1000 to <25000 · 25000 to <90000 RPMSOP-7.2.1-06 · ASTM F 2046-00 2022 · EURAMET CG-23 V1.0Why it matters

Calibration is performed according to SOP-7.2.1-06 and based on Reference Manufacture Manuals, ASTM F 2046 – 00 2022, and EURAMET CG-23 V1.0 - 02/2018.

Accurate rotational speed measurement is important for monitoring rotating equipment, evaluating performance, and identifying deviations that may affect machinery operation.

10Tachometer Devices (Mechanical / Photo)60 to <600 · 600 to <3000 · 3000 to <30000 · 30000 to <90000 RPMSOP-7.2.1-07 · ASTM F 2046-00 2022 · EURAMET CG-23 V1.0Why it matters

Calibration is performed according to SOP-7.2.1-07 and based on Reference Manufacture Manuals, ASTM F 2046 – 00 2022, and EURAMET CG-23 V1.0 - 02/2018.

Reliable tachometer calibration helps confirm rotational speed measurements used in maintenance, equipment testing, production monitoring, and mechanical performance checks.

11Timers (Stopwatch)Up to 24 hrSOP-7.2.1-08 · NIST Guide (SP-960-12)Why it matters

Calibration is performed according to SOP-7.2.1-08 and based on NIST Guide (SP-960-12).

Accurate time measurement supports repeatable testing, controlled process duration, laboratory procedures, and activities that depend on consistent timing.

Supplier-Endorsed Services

Specialized calibration & qualification for specific equipment

With over 35 years of experience in installations, maintenance, repairs, qualifications, and calibration across various fields and thanks to our esteemed multinational agencies, our calibration laboratory plays a critical role in delivering unmatched services for our unique products, supported by our highly trained engineers, who are certified and authorized by our suppliers.

Merck STERITEST Symbio sterility testing pump
STERITEST EQUINOX / SYMBIO

Sterility Tester

Sterility testing plays a critical role in the pharmaceutical industry by ensuring the quality and sterility of product batches before their release.

Read more

The qualification and calibration of Merck’s STERITEST are not standard processes; they require unique and specific hardware, software, and highly trained certified personnel to ensure accuracy and overall functionality.

Merck Mobius single-use system
Pharmaceutical Production Support

Mobius Single-Use Mixing Systems

Mobius single-use mixing systems are powerful tools in pharmaceutical production, designed to support production steps that require non-contact product systems, such as formulation, clarification, and more.

Read more

Available in various formats and volumes, they offer flexibility to meet customers’ specific requirements. As the exclusive agent for Merck KGaA Life Science in Egypt, we are fully trained and qualified to provide the necessary services, calibration, and qualification for these systems.

Merck INTEGRITEST 5 filter integrity tester
INTEGRITEST®

Filter Integrity Tester

INTEGRITEST® is one of the market leaders for integrity testing of process filtration. This testing is crucial across pharmaceutical industries and sterile-based production environments.

Read more

The qualification and calibration of Merck’s INTEGRITEST are not regular processes; they require unique and specific hardware, software, and highly trained certified personnel to ensure they are done correctly.

Along with our comprehensive coverage across Egypt and a team of highly skilled and experienced personnel, we also offer these services outside Egypt on behalf of Merck KGaA when requested.

Merck MAS-100 VF microbial air sampler
Microbial Monitoring Instrumentation

MBV MAS-100 Family Air Samplers

MBV MAS-100 family air samplers are significant microbial monitoring instrumentation at any sterile area, particularly in the pharmaceutical industry.

Read more

Air samplers are essential in sterile and clean areas to monitor the presence of aerobic bacteria in the air. Proper qualification and calibration are required to ensure correct functionality and avoid false results.

This goes beyond simple comparison-based calibration; it involves automatic flow adjustments when measurements fall outside acceptable ranges using specialized tools and compatible software.

Merck Milli-Q laboratory water purification systems
Research, Diagnostics, R&D, and Testing Laboratories

Laboratory Water Purification Systems

Laboratory water purification systems are essential and widely used in research, diagnostics, R&D, and testing laboratories. These systems provide various grades of laboratory water to meet the diverse needs of different applications.

Read more

Merck KGaA is the market leader in this field. As the exclusive agent for Merck KGaA Life Science in Egypt since 2003, we have accumulated years of valuable experience, supported by continuous productive collaboration and training with Merck KGaA.

This partnership has resulted in a team of highly qualified experts who are well-trained to perform calibration and qualification services for these systems.

Regional Service

Serving customers beyond Egypt

NOOR Scientific & Trade's after-sales capabilities extend beyond the Egyptian market, with its specialized technical teams already delivering manufacturer-endorsed services to customers across selected Middle Eastern and African markets, including Algeria, Tunisia, Senegal, Botswana, Rwanda, and Türkiye.

Working in coordination with its international technology partners, NOOR provides specialized installation, commissioning, maintenance, troubleshooting, and other technical services according to the requirements of each project and manufacturer authorization.

Manufacturer-endorsed services delivered in
  • Algeria
  • Tunisia
  • Senegal
  • Botswana
  • Rwanda
  • Türkiye

By NOOR's technical teams from Egypt, according to each project's requirements and manufacturer authorization.

Why Choose Us

Why choose Noor Scientific & Trade's calibration services?

  • Compliance with International Standards

    Calibration services aligned with recognized standards to support accuracy, reliability, and regulatory confidence.

  • Expert Calibration Performance

    Services performed by qualified specialists using appropriate tools, procedures, and professional technical knowledge.

  • Comprehensive Reporting

    Detailed measurement data and clear documentation to provide complete transparency and support quality records.

  • Reduced Downtime & Improved Lifespan

    Early detection of inaccuracies helps improve equipment lifespan, reduce downtime, and maintain stable operations.

How to Request Service

Need calibration or service support?

  1. 1Send your request with the equipment type, service requirement, application area and any relevant operational details.
  2. 2We route it to the appropriate technical team for review.
  3. 3Service & follow-up through clear communication with our service center.
After Sales Services & Calibration Center

Request After Sales or Calibration Support

Tell us about your equipment and the support you need — our service team replies within one working day.

Noor Scientific & Trade

Request Information

Share your requirements — our team will route your inquiry to the right division and reply within one working day.