Modular layout
Place sensors at the risk point and receivers in the control area.
The A14/A11 from Badger Meter (GasSens / ATi) is a modular gas detection system: sensor transmitters in the area at risk, and receiver modules with display and alarms where operators need them.

A14/A11 GasSens systems consist of individual modules that can be located where required. Sensor transmitters are installed where gas leakage or build-up might occur and provide the basic measurement; receiver modules show the gas concentration and drive the alarms.
Sensor transmitters are available in NEMA 4X or explosion-proof versions and can be supplied with the AutoTest automatic sensor testing system, which reduces manual testing. The power supply provides a power-failure relay and charges an optional battery back-up unit.
The system covers a wide range of toxic gases, including chlorine, ammonia, hydrogen sulfide, ozone, chlorine dioxide, sulfur dioxide, oxygen, acid gases and more, and is used from chemical and petrochemical plants to food processors.
Place sensors at the risk point and receivers in the control area.
Daily automatic response checks of the sensors.
Gas concentration shown on the receiver module.
Power supply with failure relay and battery charging.

DIN-rail modules with LED display, 3 alarm relays and trouble relay; 1 to 12 modules per enclosure.

60 interchangeable smart sensors, daily AutoTest, heated and remote sensor options, data logger.
Our Biotechnology team in Egypt will help you choose the right configuration, sensors and accessories for your site.
Explore other products available within the same product category and open each page for complete technical details.
60 interchangeable smart sensors, daily AutoTest, heated and remote sensor options, data logger.
Explosion-proof detector for up to 46 toxic and combustible sensors; loop, HART, relays or Modbus.
Explosion-proof 0–100% LEL transmitter, optional LCD and latching alarm relay.
NDIR transmitter for methane, hydrocarbons and CO2; ATEX / IECEx, HART or Modbus.
Infrared NH3 detector from ppm to explosive levels; no known sensor poisons.
Wet H2S sensor with automatic air purge, 0–2/20/200 ppm, two relays and data logger.
Loop-powered transmitter with 100% RH sensor for Cl2, Br2, ClO2, O3, HCl, HF and H2.
Loop-powered 4-20 mA transmitter for many gases; battery-capable and explosion-proof option.
Intrinsically safe version of the F12 with smart sensors, AutoTest and HART option.
Two H2O2 channels (0–2000 and 0–100 ppm) for sterilisation cycle validation.