Columns & Flow
- Works with 3 columns in parallel.
- Flow rate: 1 to 120 L/h (16 mL/min to 2000 mL/min).
- In-line buffer dilution (up to 6 buffers).
Merck Mobius Multi Column Capture System from Merck is a fully automated single-use chromatography system for continuous bind/elute in intensified and continuous biopharmaceutical processing.
Review the confirmed product information, including description, features, benefits, and applications.
The Mobius Multi Column Capture System (MCC) belongs to a family of multi-column single-use chromatography systems. It is fully automated for continuous bind/elute in intensified and continuous processing.
Flow paths have been evaluated for continuous processing for up to 20 days prior to exchange.
Reduces cost through protein A resin optimization and lower buffer consumption.
Improves throughput and productivity.
Gives high flexibility for intensified and continuous processes.
The Mobius MCC system is used for chromatography applications in the biopharmaceutical industry.
Continuous bind/elute capture chromatography.
Chromatography in intensified and continuous biopharmaceutical processes.
Share your molecule, resin type, column size, flow rate and number of buffers and our Pharma & FMCGs team will support you with the suitable product information.
Explore other products available within the same product category and open each page for complete technical details.
Multi-use, fully automated process-scale TFF for UF/DF and microfiltration, from 2.0 to 17.1 m² filter area.
Single-use TFF system with 500 L and 200 L tanks, up to 80 L/min flow and up to 20 m² membrane area.
Single-use TFF capsules with Ultracel void-free composite membrane, gamma sterilized and preservative-free.
Single-use virus filtration skid for 200 L to 2000+ L with Viresolve Pro holder and pH/conductivity.
Virus filtration solution with ≥ 4.0 log parvovirus removal, high flux and a disposable flow path.
Multi-use chromatography system with QuikScale, IsoPak and Vantage columns, from lab to process scale.
Single-use chromatography system for processes up to 2000L with flow rates up to 20L/min and 5:1 turndown.
Share your requirements — our specialists reply within one working day.
Share your requirements — our team will route your inquiry to the right division and reply within one working day.