Fixed Gas Detector

Titan 2 Fixed Benzene Monitor

Fixed Gas Detector from ION Science

Titan 2 has continuous, real-time measurement allowing trends to be monitored over time, and communicated via 4-20 mA or RS485.

Manufactured byION Science
ION Science logo
Titan 2 Fixed Benzene Monitor fixed gas detector by ION Science
Overview

About Titan 2 Fixed Benzene Monitor

Titan 2 benzene gas monitor incorporates the NEW MiniPID T2 10.0 eV Sensor which offers improved sensitivity, dependability and overall performance. The unique sampling method eliminates interfering gases such as toluene, xylene and methane providing you with accurate benzene concentration readings you can rely on.

Titan 2 offers a world major solution for the detection of benzene, providing precise detection at levels as low as 0.02 ppm (20 ppb) and as high as 20 ppm within 60 seconds. Titan 2 benzene gas monitor has been specifically engineered to analyse airborne dangers and can be utilised to evaluate the efficiency of purification or vapour recovery systems/units (VRU).

Titan 2 benzene gas monitor has obtained certification for use in ATEX zoned environments and locations. Furthermore, the enclosure is IP65 rated, offering dependable protection against the intrusion of dust and water.

Key Features

Why choose Titan 2 Fixed Benzene Monitor

New MiniPID T2 10.0 eV Sensor – Unique to Titan 2.

Low Detection Limit – Can detect benzene down to 0.02 ppm (20 ppb).

IP65 – Protection against a range of atmospheric conditions.

4-20 mA & RS485 Communication Options – Connect to your own control system.

Accessory Kit (9 Way Connector, 5 Way Connector, 2 mm Allen Key, 2.5 mm Allen Key, 3 mm Allen Key, Actuation Magnet)

Documentation (Safety Notice, Responsibility of Correct Use, Calibration Certificate)

Technical Data

Titan 2 Fixed Benzene Monitor technical data

Sensor Type
MiniPID T2 10.0 eV Sensor
Sensitivity
Benzene specific within typical petrochemical matrix
Detectable Range
0.02 ppm – 20 ppm
Measuring Frequency
One Minute
Lower Level of Detection
0.02 ppm (20 ppb) (10 ppb resolution)
Accuracy
+/- 50 ppb or +/- 10%, whichever is greater*
Temperature Stability
Internally heated
Flow Rate
Sample flow rate ≥ 100 ml/min
Display
Graphic BW LCD 64 x 128 pixels with backlight Bright LEDs for normal operation, fault and alarm Two magnetic switches for menu operation
Operating Temperature
Recommended operating range of -20 oC to +50 oC (-4 oF to +122 oF) for optimum performance**
Approvals
4FTZU 14 ATEX 0172X Ex II 2G Ex db IIB+H2 T4 Gb Tamb. = -20 oC to +55 oC IECEx FTZU 14.0030X Ex db IIB+H2 T4 Gb Tamb. = -20 oC to +55 oC QPS LR1621-1 Ex db IIB+H2 T4 Gb AEx db IIB+H2 T4 Gb Ta= -20 oC to +55 oC
Ingress Protection Rating
IP65
Humidity
0 – 99 % RH
Minimum Service Period
6 months – PID lamp, electrode stack, inline filter, VRV restrictor, Hydrophobic & carbon filter replacement
Cable Entry
Two ¾ NPT gland threads
Power Requirements
Vin (nom) 24 V DC @ 3.2 A (recommended) Vin (max) 32 V DC @ 2.4 A Vin (min) 19 V DC @ 4.0 A
Communication
Isolated 4-20 mA output
Data Storage
On board MMC, minimum of six months (2GB)
Relay Output
Two isolated outputs, voltage free, 24 v DC @ 1.25 A
Weight and Dimensions
15 kg (33 lbs) 219 x 219 x 172 mm (8.6 x 8.6 x 6.8” approx.)
Gas Sample Line
10 m max length, PTFE, 6 mm OD, 4 mm ID *± 10 ppb for readings ≤ 0.1 ppm **+55 oC = ± 20% accuracy
Works With

Related products

Falco 2 Fixed VOC Gas Detector by ION Science
Fixed Gas Detector

Falco 2 Fixed VOC Gas Detector

The Falco Diffused is a fixed voc gas detector that eliminates false readings found with other competing technology, for the detection of toxic gases.

TVOC 2 Continuous VOC Monitor by ION Science
Fixed Gas Detector

TVOC 2 Continuous VOC Monitor

TVOC 2 is a fixed, continuous VOC gas detector that accurately detects/measures Total Volatile Organic Compounds within industrial working…

Need a quotation or technical advice on Titan 2 Fixed Benzene Monitor?

Our Biotechnology team in Egypt will help you choose the detector, sensors and accessories, and arrange calibration and service.

Request Information
Gas Detection & Safety

Other Products in Fixed Gas Detectors

Explore other products available within the same product category and open each page for complete technical details.

Biotechnology Division

Request Biotechnology Information

Share your requirements — our specialists reply within one working day.

Noor Scientific & Trade

Request Information

Share your requirements — our team will route your inquiry to the right division and reply within one working day.